Neutral / Earthing / Zig-Zag TransformersRepresentative image
Transformers

Neutral / Earthing / Zig-Zag Transformers

LV up to MV (e.g. 415 V…zig-zag (interconnected…e.g. 10 s, 30 s…

Neutral / earthing / zig-zag transformers create an artificial neutral (ground reference) on a three-phase system that has no accessible neutral — most often a delta-connected or otherwise ungrounded supply — so the system can be earthed and ground faults detected and cleared safely.

Overview

Neutral / earthing / zig-zag transformers create an artificial neutral (ground reference) on a three-phase system that has no accessible neutral — most often a delta-connected or otherwise ungrounded supply — so the system can be earthed and ground faults detected and cleared safely. The classic form is the zig-zag (interconnected-star) transformer: each limb carries interleaved sections of two phases so the winding presents high impedance to normal balanced (positive/negative-sequence) currents but a low zero-sequence impedance path to ground, letting it pass earth-fault current while drawing only small magnetizing current in healthy operation. The derived neutral is usually taken to ground through a Neutral Grounding Resistor (NGR) or reactor to limit fault current to a chosen value. These units are short-time rated (sized to carry full fault current for a defined time such as 10 s or 30 s) and are specified by system voltage, fault current, duration and zero-sequence impedance. A buyer needs one wherever an ungrounded/delta system must be solidly or impedance-earthed for protection.

Specifications

Standard parameters — confirmed on enquiry
System voltage / voltage classLV up to MV (e.g. 415 V to 33 kV)
Connectionzig-zag (interconnected star) or grounded wye-delta
Continuous neutral current rating and ground-fault (short-circuit) current
Short-time rating / duratione.g. 10 s, 30 s, or continuous
Zero-sequence impedanceengineered to set fault-current division
Phasesthree-phase
Frequency50 / 60 Hz
NGR / NGT (resistor or reactor) integration to limit fault current
Cooling/constructiondry-type or oil-filled; indoor/outdoor
Insulation/thermal class and BIL per voltage class
StandardsIEC 60076-6 / IEEE C57.32 / IEEE C62.92; IS where applicable

Applications

  • Deriving a neutral on delta / ungrounded three-phase systems
  • Resistance- or reactance-earthing (with NGR/NGT)
  • Ground-fault detection and protection coordination
  • Generator and transformer-secondary grounding
  • Industrial, distribution and utility earthing schemes
Built to specification. Custom ratings, voltages and enclosures available — share your single-line diagram and duty cycle and we'll engineer the unit to match. Specifications shown are standard ranges and are confirmed against your requirement on enquiry. Standards & glossary reference →

Frequently asked questions

Do you build custom transformers to specification?
Yes — every unit is engineered to your ratings, voltage, frequency and enclosure. Send your single-line diagram and duty cycle and we build the transformers to match.
What quality standard does ACE Electromagnetics work to?
An ISO 9001:2015 quality management system; units are designed and tested to the relevant IEC and IEEE standards for the product type.
How soon will I get a response to a quote request?
Our engineering team replies to quote requests within one business day.
Are the specifications shown on this page final?
They are standard ranges; the final rating is confirmed against your specific requirement on enquiry.

Request a quote — Neutral / Earthing / Zig-Zag Transformers

Tell us your application and ratings. Our engineering team replies within one business day.

What we need to quote

  • kVA / VA or current rating
  • Primary & secondary voltage
  • Frequency (50 / 60 / 400 Hz)
  • Phase (1-ph / 3-ph)
  • Cooling, mounting & enclosure (IP)
  • Application / end-use

Share what you have — we confirm the rest with you.

We reply within 1 business day.