A regenerative (active) load system replaces a conventional resistive/reactive load bank used to test equipment such as alternators, motors, transformers, battery chargers, DG sets and rectifiers.
Overview
A regenerative (active) load system replaces a conventional resistive/reactive load bank used to test equipment such as alternators, motors, transformers, battery chargers, DG sets and rectifiers. Instead of dissipating the full test power as heat in resistor or salt-water banks, ACE's IGBT-based system is grid-tied ('grid-locked') and feeds the test power back into the user's own 3-phase grid for reuse — so the source only has to supply the system's loss (efficiency-loss) power rather than the full load power. Buyers choose it to drastically cut the energy wasted during full-load testing, avoid the heat and footprint of dump-load banks, and obtain a controllable, dynamic electronic load with low injected current harmonics. (Existing site: IGBT-based, regenerates power for active use, takes only system active-loss power from the source, current harmonics THDi < 10%.)
Specifications
| Topology | IGBT-based active front-end, grid-tied / grid-locked regeneration (existing site) |
|---|---|
| Function | regenerates test power back into user's 3-phase grid (existing site) |
| Source draw | only the system's active loss power, not full load power (existing site) |
| Current harmonics | THDi < 10% (existing site) |
| Power rating | built to test-target rating (class: tens of kW to MW range) |
| Grid connection | three-phase, 415 V class (50/60 Hz) |
| Load type emulated | active (real) power load, dynamically controllable |
| Control | dynamic / programmable load profile |
| Applicable standards | grid-interface / harmonic limits per IEEE-519 / IEC 61000 class |
Applications
- Full-load testing of alternators and generators
- Motor load / endurance testing
- Testing power transformers, rectifier units and battery chargers
- DG-set load testing without resistive dump load
- Energy-saving replacement for resistive / salt-water load banks
Request a quote — ACE Regenerative Systems
Tell us your application and ratings. Our engineering team replies within one business day.
More in Power Electronics & Conditioning

1PH - 3PH Inverters
A power inverter converts DC input (from batteries, rectifiers, solar arrays or a DC bus) into clean

ACE Thyristor PFC Modules
A thyristor PFC (power-factor-correction) switching module is a solid-state alternative to electrome

Static Compensators (STATCOM)
A STATCOM (Static Synchronous Compensator) is a shunt-connected FACTS device that uses an IGBT volta