ACE Line Chokeplaceholder · competitor · indiamart.com
Reactors & Inductors

ACE Line Choke

line/load current plus hLV (e.g. 415 / 440 / 69050 / 60 Hz

The ACE Line Choke is ACE's series line/AC choke for limiting current and mitigating harmonics on the supply side of non-linear loads and capacitor banks.

Overview

The ACE Line Choke is ACE's series line/AC choke for limiting current and mitigating harmonics on the supply side of non-linear loads and capacitor banks. As the existing site frames it, the rising use of modern electronics raises harmonic current demand (THDi), which raises supply voltage distortion (THDv); this distortion can resonate with shunt PFC capacitors and cause harmonic amplification, capacitor/transformer/line overloading, voltage distortion and interference with metering and controls. The line choke is connected in series to add inductive reactance that smooths current rise, attenuates harmonic and switching components, and protects downstream capacitors and equipment. ACE builds these as dry-type, naturally-cooled, H-class wound reactors on laminated cores, rated to the line/load current with impedance or inductance specified per the application. Buyers choose ACE for a robust series choke matched to their harmonic and current-limiting requirement.

Specifications

Standard parameters — confirmed on enquiry
Inductance (mH) / impedance (%Z) specified per application
Rated current (A)line/load current plus harmonic loading
Voltage classLV (e.g. 415 / 440 / 690 V) as specified
Frequency50 / 60 Hz
Phasesthree-phase (single-phase on request)
Harmonic / current-rise limiting; high-harmonic-environment capability
InsulationClass H; low noise
Coolingnatural air (dry type); low watt-loss per kg
Mountingpanel / floor; Enclosure: open IP00 / enclosed as specified
Applicable standardsIEC 60076-6, IEEE-519, IS/IEC

Applications

  • Series line-side choke for harmonic and current-rise limiting (existing site context)
  • Protecting shunt PFC capacitors from resonance and overloading (existing site context)
  • Input buffering for rectifiers, drives and non-linear loads
  • Reducing voltage distortion and metering/control interference (existing site context)
  • Power-conditioning and line-pollution mitigation
Built to specification. Custom ratings, voltages and enclosures available — share your single-line diagram and duty cycle and we'll engineer the unit to match. Specifications shown are standard ranges and are confirmed against your requirement on enquiry.

Request a quote — ACE Line Choke

Tell us your application and ratings. Our engineering team replies within one business day.