Passive Broad Band Harmonic Filterplaceholder · competitor · tiimg.tistatic.com (TradeIndia)
Harmonic & Electric Filters

Passive Broad Band Harmonic Filter

typically 5 HP to ~500 HLV 380-480 V / 415 V / ubroadband series low-pas

A passive broad-band harmonic filter (BBF) is a wide-bandwidth LC filter that attenuates a continuous band of harmonic frequencies rather than being sharply tuned to single orders, avoiding the resonance problems of conventional shunt-tuned filters.

Overview

A passive broad-band harmonic filter (BBF) is a wide-bandwidth LC filter that attenuates a continuous band of harmonic frequencies rather than being sharply tuned to single orders, avoiding the resonance problems of conventional shunt-tuned filters. ACE's broadband design (existing site) pairs a series low-pass section with a shunt high-pass section so the filter behaves as the local source for the load's harmonic demand, cutting harmonics at the supply end while improving system power factor — a 'two-in-one' benefit. Because it uses no electronics, control algorithms or firmware, it is rugged, maintenance-free, reliable and inexpensive, and is easy to retrofit near the load to reduce bus-duct I²R losses and skin effect. Buyers choose the broad-band variant over simple shunt-tuned filters where they want stable, resonance-free harmonic mitigation across many 6-pulse VFD loads without the cost and complexity of active solutions.

Specifications

Standard parameters — confirmed on enquiry
Power/HP rangetypically 5 HP to ~500 HP per unit (extendable to MW-class for large drives)
Voltage classLV 380-480 V / 415 V / up to 690 V, 3-phase, 50/60 Hz
Topologybroadband series low-pass + shunt high-pass LC (not single-frequency tuned) (existing site)
THDitypically reduced to ~5-8% at full load to meet IEEE-519
Configuration3P3W (balanced load) and 3P4W (corrects up to 25% unbalance) (existing site)
Resonancebroadband response avoids resonance with transformer/source impedance (existing site)
Componentsfully passive — reactors + capacitors, no electronics or control firmware (existing site)
Mounting/enclosureframe-mount IP00 or cabinet IP20/IP54; install close to load
Coolingnatural / forced air
Applicable standardsIEEE-519, IEC 61000-3, IS 2026 / IEC 60076 (reactors)

Applications

  • Front-end six-pulse DC rectifiers (existing site)
  • VFDs and motor applications (existing site)
  • Automation equipment (existing site)
  • HVAC equipment using motor drives (existing site)
  • Waste-water / effluent treatment plants (existing site)
  • Battery chargers (existing site)
Built to specification. Custom ratings, voltages and enclosures available — share your single-line diagram and duty cycle and we'll engineer the unit to match. Specifications shown are standard ranges and are confirmed against your requirement on enquiry.

Request a quote — Passive Broad Band Harmonic Filter