Harmonic & Electric Filters

Active Harmonic Filters

typically 30 A to 150 A 208-415 V (up to 690 V),IGBT PWM active front-en

An active harmonic filter (AHF) is a shunt-connected IGBT PWM power converter that continuously measures load current, computes the harmonic and reactive components, and injects equal-and-opposite harmonic currents in real time to cancel distortion at the point of connection.

Overview

An active harmonic filter (AHF) is a shunt-connected IGBT PWM power converter that continuously measures load current, computes the harmonic and reactive components, and injects equal-and-opposite harmonic currents in real time to cancel distortion at the point of connection. Unlike a passive filter it adapts dynamically to changing loads, corrects multiple harmonic orders simultaneously, and can also deliver reactive-power / power-factor correction and load balancing. ACE's unit (existing site) conditions current distortion in under 5 ms and drives system THDi below 10% (typically <5% at the PCC), eliminating neutral overloading and reducing I²R and transmission losses. Buyers select an AHF for installations with highly variable or mixed non-linear loads where guaranteed IEEE-519 compliance, near-unity power factor and future expandability matter more than first cost; rating is by harmonic compensation current (amps), so multiple modules can be paralleled.

Specifications

Standard parameters — confirmed on enquiry
Compensation current ratingtypically 30 A to 150 A per module (existing site implies modular); parallel modules to several hundred / thousand amps
Voltage class208-415 V (up to 690 V), 3-phase 3-wire and 3-phase 4-wire (with neutral compensation), 50/60 Hz
TopologyIGBT PWM active front-end converter, DSP closed-loop control
Response timefull correction within < 5 ms; transient response in the tens of microseconds (existing site: <5 ms)
THDi resultsystem THDi < 10% (existing site), commonly down to <5% per IEEE-519
Harmonic orders correctedselectable up to ~50th order
Functionsharmonic cancellation + reactive/PF correction (lead/lag) + load balancing
Mountingwall-mounted, rack/cabinet, or floor-standing modular
Coolingforced-air (fan-cooled); efficiency typically >97%
Applicable standardsIEEE-519, IEC 61000-3 / 61000-4

Applications

  • Data centres and IT/UPS loads with mixed non-linear equipment
  • Buildings/HVAC with many small VFDs and variable load
  • Hospitals and commercial facilities requiring power-quality compliance
  • Manufacturing plants with fluctuating drive and welding loads
  • Neutral-current / I²R loss reduction in 3P4W distribution (existing site)
  • Power-factor and IEEE-519 compliance where passive filters cannot adapt
Built to specification. Custom ratings, voltages and enclosures available — share your single-line diagram and duty cycle and we'll engineer the unit to match. Specifications shown are standard ranges and are confirmed against your requirement on enquiry.